HOME COMPANY PROFILE NEW PRODUCTS ENGLISH / CHINESE WARRANTY
Product classification
  ANRITSU METER
TEMPERATURE PROBES
THERMOMETERS
ACCESSORIES
TECHNICAL GUIDE
SITE MAP
DOWNLOAD
  OMEGA
Conductivity
Data Logger
Environmental
Calibrator
Air Velocity Meters
Level
Lab Equipments
Pressure
Power Monitoring
PH Meter
Recorders
Temperature
Test & Measurement
Flow
New Products
Temperature Calibration System   Model  ACSⅡ  series
Model ACSⅡ series products are temperature calibration systems for surface temperature and internal temperature measuring devices. Temperatures can be set across a wide range, from room temperature to 500°C. These calibration systems are designed for calibration or to check temperature measuring probes.
How to order

ACSⅡ-1000 For Surface Temperature Max. 300°C

Temperature Calibration System

ACSⅡ-2000 For Surface Temperature Max. 500°C

Temperature Calibration System

Please specify a power supply voltage when ordering (choose from 100 VAC, 115 VAC, or 230 VAC)

Specifications

Overall Accuracy

Model

ACSⅡ-1000

ACSⅡ-2000

ACSⅡ-3000

ACSⅡ-4000

Calibration Object

Surface

Internal

Surface

Internal

Range

Rt to 100°C

+0.5 / -0.7°C

+0.5 / -0.7°C

±0.26°C

+0.4 / -0.6°C

±0.26°C

100 to 200°C

+0.5 / -1.1°C

+0.5 / -1.1°C

±0.32°C

+0.3 / -0.9°C

±0.32°C

200 to 300°C

+0.5 / -1.5°C

+0.5 / -1.5°C

±0.37°C

+0.1 / -1.1°C

±0.37°C

300 to 400°C

+0.4 / -2.0°C

±0.43°C

+0.2 / -1.5°C

±0.43°C

400 to 500°C

-0.1 / -2.9°C

±0.48°C

-0.9 / -2.2°C

±0.48°C

Control Unit

Model

ACSⅡ-1000

ACSⅡ-2000

ACSⅡ-3000

ACSⅡ-4000

Surface Range

Rt to 300°C

Rt to 500°C

Rt to 500°C

Internal Range

Rt to 500°C

Rt to 500°C

Control Principle

PID auto-Tuning Control

Control

Input

Pt 100Ω, ø3.2 Class A

Accuracy

±(0.2% of reading)°C

Display

8mm high LED display

Reference
Sensor

Input

Pt 100Ω, ø4.8 Class A

Accuracy

±(0.05% of reading +0.05)°C

Display

12.5mm high LED display

Power Consumption

App.160W

App.700W

App.1600W

Dimensions (mm)

320(W)×177(H)×350(D)

430(W)×177(H)×350(D)

Weight

App.4.5kg

App.5.0kg

Calibration Unit

Model

ACSⅡ-1000

ACSⅡ-2000

ACSⅡ-3000

ACSⅡ-4000

Testing Surface (mm)

ø78

ø100

150×150

Test Point

8 holes based on specified dimension

Temp. Distribution

±0.1°C

Heater

150W

600W

1500W

Dimensions (mm)

260(W)×130(H)×260(D)

390(W)×230(H)×360(D)

450(W)×405(H)×400(D)

Weight

App.7kg

App.20kg

App.70kg

Overheating prevention mechanism

Bimetal breaker

Heating time

Rt → 150°C 20min

Rt → 250°C 20min

Rt → 250°C 60min

Rt → 300°C 40min

Rt → 500°C 50min

Rt → 500°C 150min

Cooling time

300 → 150°C 20min

500 → 250°C 30min

500 → 250°C 220min

150 → 50°C 40min

250 → 50°C 70min

250 → 100°C 430min

 

Copyright @ 2013 www.AnLiXinYi.com All Right Reserved
Phone :024-2318 0560 2318 0650 Fax :024-2318 0512 E-mail: AnLiXinYi@163.com
Copyright Shenyang An Lixin Instrument Co., Ltd. works for this site without permission are not allowed to reprint all the information LTD.All rights reserved