Fiber Optic Thermometer   Model  FL  series  

 

1ch. FL-2000 Specifications

Type

FL-2000

Input point

1

Measurement range

-195.0°C to 450°C

Resolution

0.1°C

Accuracy

Calibration not executed

-195.0 to 399.9°C : ±2°C, 400.0 to 450.0°C : ±5°C

Calibration executed

±0.5°C (within ±50°C of caribration point)
(at an ambient temp. of 25°C±5°C)

Temperature coefficient

±(0.01% of F.S./°C) within operating temperature

Operating environment

Temperature : 0 to 40°C
Humidity : 15 to 80%RH(non-condensing)

Storage environment

Temperature : -10 to 50°C
Humidity : 10 to 85%RH(non-condensing)

Display

Height of character : 15mm RED LED

Display update

1s

Light source

Blue LED

Power
supply

AC power

Please specify a supply voltage when ordering
(choose from 100VAC, 115VAV, or 230VAC)

Dry battery

six AA-size alkaline batteries

Power consumption

approx. 12 VA

Memory

UP to 15,000 data, one second interval
(synchronized with display)

Interface

RS-232C Transfer rate : 9600bps
Data formation : 7bit, odd parity, 1 stop bit

Calibration

One-point calibration
(using real temperature within a measured area)

Analog output

Output rate

10mV/°C

Resolution

1mV

Accuracy

±(0.2% of F.S) at an ambient temperature of 25°C±5°C

Temperature coefficient

±(0.01% of F.S/°C)

External dimensions

210(W)×88(H)×230(D) mm
Protruded parts excluded

Weight

aoorox. 3kg

Supplied accessory

Power cable(two-wire plug attached)×1
Fuse(2A mini fuse)×1
Analog output cable×1
communication cable×1
PC software AMS-850 (CD ROM)×1
User's manual(main unit and software)×1

4ch. FL-2400 Specifications

Type

FL-2400

Input point

4

Measurement range

-195.0°C to 450°C

Resolution

0.1°C

Accuracy

Calibration not executed

-195.0 to 399.9°C : ±2°C, 400.0 to 450.0°C : ±5°C

Calibration executed

±0.5°C (within ±50°C of caribration point)
(at an ambient temp. of 25°C±5°C)

Temperature coefficient

±(0.01% of F.S./°C) within operating temperature

Operating environment

Temperature : 0 to 40°C
Humidity : 15 to 80%RH(non-condensing)

Storage environment

Temperature : -10 to 50°C
Humidity : 10 to 85%RH(non-condensing)

Display

Height of character : 8mm RED LED

Display update

1s

Light source

Blue LED

Power supply

Please specify a supply voltage when ordering
(choose from 100VAC, 115VAV, or 230VAC)

Power consumption

approx. 40 VA

Memory

No memory

Interface

RS-232C Transfer rate : 9600bps
Data formation : 7bit, odd parity, 1 stop bit

Calibration

One-point calibration
(using real temperature within a measured area)

Analog output

Output rate

10mV/°C

Resolution

1mV

Accuracy

±(0.2% of F.S) at an ambient temperature of 25°C±5°C

Temperature coefficient

±(0.01% of F.S/°C)

External dimensions

320(W)×99(H)×280(D) mm
Protruded parts excluded

Weight

approx. 5kg

Supplied accessory

Power cable(two-wire plug attached)×1
Fuse(2A mini fuse)×1
Analog output cable×1
communication cable×1
Conversion cable(RS-232C→USB)
PC software AMS-850 (CD ROM)×1
User's manual(main unit and software)×1

 

Copyright @ 2013 www.AnLiXinYi.com All Right Reserved
Phone :024-2318 0560 2318 0650 Fax :024-2318 0512 E-mail: AnLiXinYi@163.com
Copyright Shenyang An Lixin Instrument Co., Ltd. works for this site without permission are not allowed to reprint all the information LTD.All rights reserved