Compact Thermologger   Model  AM-8000  series  

 

Specifications of AM-8000 series

6ch.model

Model

AM-8000

AM-8001

AM-8100

AM-8101

Input Type

Temperature

Measurement Range

Table 1

Resolution

0.1°C / 1°C (fixed)

Measurement Accuracy

Table 3

Memory capacity

60,000 data

High-speed interval

1 second

0.1 seconds

1 second

0.1 seconds

Interface

USB1.1

RS-232C

Dimensions / Weight

92(W) × 155(H) × 36(D) mm [Protruded parts excluded] / approx.380g [Including dry batteries]

Model

AM-8050

AM-8051

AM-8150

AM-8151

Input Type

Temperature / DC Voltage

Measurement Range

Temperature : See Table 1
DC Voltage : ±19.999V

Resolution

Temperature : 0.1°C / 1°C (fixed)
DC Voltage : 0.001V

Measurement Accuracy

Temperature : Table 3
DC Voltage : ± (0.06% of reading + 0.02% of F/S)

Memory capacity

60,000 data

High-speed interval

1 second

0.1 seconds

1 second

0.1 seconds

Interface

USB1.1

RS-232C

Dimensions / Weight

92(W)×155(H)×36(D) mm [Protruded parts excluded] / approx.380g [Including dry batteries]

12ch.model

Model

AM-8010

AM-8011

AM-8110

AM-8111

Input Type

Temperature

Measurement Range

Table 1

Resolution

0.1°C / 1°C (fixed)

Measurement Accuracy

Table 3

Memory capacity

120,000 data

High-speed interval

1 second

0.2 seconds

1 second

0.2 seconds

Interface

USB1.1

RS-232C

Dimensions / Weight

96(W)×160(H)×60(D) mm [Protruded parts excluded] / approx.480g [Including dry batteries]

Model

AM-8060

AM-8061

AM-8160

AM-8161

Input Type

Temperature / DC Voltage

Measurement Range

Temperature : Table 1
DC Voltage : ±19.999V

Resolution

Temperature : 0.1°C / 1°C (fixed)
DC Voltage : 0.001V

Measurement Accuracy

Temperature : Table 3
DC Voltage : ± (0.06% of reading + 0.02% of F/S)

Memory capacity

120,000 data

High-speed interval

1 second

0.2 seconds

1 second

0.2 seconds

Interface

USB1.1

RS-232C

Dimensions / Weight

96(W)×160(H)×60(D) mm [Protruded parts excluded] / App.480g [Including dry batteries]

Common specifications

Input connector

ANP connector (Miniature Plug)

Reference junction
compensation accuracy

±0.3°C at 25°C ± 10°C

Temperature coefficient

±(0.01% / °C) of measurement range except 25°C ± 10°C

Time interval *

Standard model : 1 second to 99 minutes 59 seconds
High-speed mode (6ch.model) : 0.10 seconds to 0.99 seconds
High-speed mode (12ch.model) : 0.20 seconds to 0.99 seconds

Signal source resistance

Temperature : 500Ω or less (standard mode), 100Ω or less (high-speed mode)
DC Voltage : input impedance app.2MΩ or less

Safe excitation voltage

Between input pins on same channels : ±10V DC (temperature), ±30V DC (voltage)
Between input pins on adjacent channels : ±60V AC

Linearlizer

Digtal Linearlizer method (compliant with IEC 60584-1 (1995))

Interface

USB 1.1 MINI-B / RS-232C (selected at purchase)

Display

Graphic liquid crystal display, 128×64 dots (55×27mm)

Environment operational

0 to 40°C, 20 to 80%RH (Without Dew)

Environment storage

-10 to 50°C, 10 to 90%RH (Without Dew)

Power supply

4 AA Alkaline batteries or AC adapter (Option accessories)

Supplied accessories

4 AA Alkaline batteries, Test report, Manual, Softcase, Communications cable (USB or RS-232C)

Optional accessories

AC-Adapter, Special data analysis software (AMS-850), Carrying case

Compatible standards

CE Making, RoHS

* In the case of remote measurement through a PC : 1 second to 99 minutes 59 seconds

Table 1 : Measurement Range

Type

1°C Range

0.1°C Range

E

-200 to 800°C

-100.0 to 500.0°C

K

-200 to 1370°C

J

-200 to 1100°C

T

-200 to 400°C

-100.0 to 400.0°C

R

0 to 1760°C

*Switches automatically to 1°C resolution range when measured temperatures fall outside the 0.1°C resolution range.

Table 2 : Battery life

Interval

0.1 sec

1 sec

10 sec

10 min

Battery life

approx. 20h

approx. 40h

approx. 80h

approx. 240h

*Note : When operated with alkaline AA-size dry batteries at 25°C typ.

Table 3 : Measurement accuracy

Type

Resolution

Measurement range

Measurement accuracy

Type E, K, J, T

1°C

0°C to

± (0.1% of reading + 1°C)

-100 to -1°C

± (0.5% of reading + 1°C)

-200 to -101°C

± (1% of reading + 2°C)

0.1°C

0.0°C to

± (0.1% of reading + 0.3°C)

-100.0°C to -0.1°C

± 0.5°C

Type R

1°C

0 to 1760 °C

± (0.1% of reading + 3°C)

*Not including reference junction compensation accuracy, at 25°C ± 10°C

Supplied accessories

Soft case

Communication Cable USB

Communication Cable RS-232C

Optional accessories

AC-Adaptor

Carrying Case

 

Copyright @ 2013 www.AnLiXinYi.com All Right Reserved
Phone :024-2318 0560 2318 0650 Fax :024-2318 0512 E-mail: AnLiXinYi@163.com
Copyright Shenyang An Lixin Instrument Co., Ltd. works for this site without permission are not allowed to reprint all the information LTD.All rights reserved