Handheld Thermometer   Model  HD-1300  series  

 

Specifications of HD-1300 series

Model

HD-1300
HD-1350

HD-1301
HD-1351

HD-1302
HD-1352

Waterproof specifications
(Equivalent to IPX5)

Display

LCD with Backlight

Input connector

ASP model: HD-1*0* / ANP model: HD-1*5*

Channel

1ch

Input type

Thermocouple Input: Type E, K (HD-1*0*) Not switchable
Thermocouple Input: Type E, K, J, T or R (HD-1*5*) Not switchable

Signal source resistance

MAX 500Ω

Measurement Range

Table 1

Measurement Accuracy

Table 2

Reference junction
compensation accuracy

±0.2°C at 25°C±10°C [±0.4°F at 77°F±18°F]

Temperature Coefficient

±0.01% of F/S per °C [±0.01% of F/S per °F] (F/S : full scale)

Environment

Operation

0 to 40°C, 0 to 80%RH (Non condensing)
32 to 104°F, 0 to 80%RH (Non condensing)

Storage

-20 to 50°C, 0 to 85%RH (Non condensing)
-4 to 122°F, 0 to 85%RH (Non condensing)

Battery life

300 h

150 h

150 h

Power supply

Dry battery

4 AA Alkali Batteries

AC power

AC-Adaptor (Option)

Sampling rate

approx.300ms

Plinearlizer

Digital Linearizer method (Compliant with IEC 60584-1 (1995))

Dimensions

approx. 76(w)×167(H)×36(D) mm [Protruded parts excluded]

Weight

approx. 350g [Include Batteries]

Supplied accessories

Alarm output Cable

Analog output Cable

Analog Output

1mV/°C (Table 3)

10mV/°C (Table 3)

Alarm Output

◯ (Table 4)

◯ (Table 4)

◯ (Table 4)

Memory function

°C / °F Change

Compatible standards

CE Marking, RoHS

Table 1 : Measurement Range

Thermocouple Type

°C

1°C Resolution

0.1°C Resolution

E

-200 to 800°C

-100.0 to 500.0°C

K

-200 to 1370°C

J

-200 to 1100°C

T

-200 to 400°C

-100.0 to 400.0°C

R

0 to 1760°C

Thermocouple Type

°F

1°F Resolution

0.1°F Resolution

E

-328 to 1472°F

-148.0 to 932.0°F

K

-328 to 2498°F

J

-328 to 2012°F

T

-328 to 752°F

-148.0 to 752.0°F

R

32 to 3200°F

* Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.

Table 2 : Measurement Accuracy

Type

°C

E, K, J, T

0.1°C Resolution

0°C to

± (0.05% of reading + 0.2°C)

to 0°C

± 0.5°C

1°C Resolution

0°C to

± (0.1% of reading +1°C)

to 0°C

± (0.5% of reading +1°C)

R

1°C Resolution

± (0.1% of reading +3°C)

Type

°F

E, K, J, T

0.1°F Resolution

32°F to

± (0.05% of reading + 0.4°F)

to 32°F

± 0.5°F

1°F Resolution

32°F to

± (0.1% of reading + 2°F)

to 32°F

± (0.5% of reading +2°F)

R

1°F Resolution

± (0.1% of reading +6°F)

Table 3 : Analog Output

Environment

Accuracy

25°C±5°C

± (0.15% of F/S + 1mV)

Except 25°C±5°C

± ((0.15% of F/S + 1mV)+(0.01% of F/S))

* Output Impedance 100Ω * F/S : full scale

Table 4 : Alarm Output

Output Pattern

Upper Limit

Lower Limit

More than upper limit

H (5V)

L (0V)

Between upper and lower limit

L (0V)

L (0V)

Less than lower limit

L (0V)

H (5V)

* Signal current of up to 5mA can be taken out.

 

Copyright @ 2013 www.AnLiXinYi.com All Right Reserved
Phone :024-2318 0560 2318 0650 Fax :024-2318 0512 E-mail: AnLiXinYi@163.com
Copyright Shenyang An Lixin Instrument Co., Ltd. works for this site without permission are not allowed to reprint all the information LTD.All rights reserved