RTD Thermometer   HH376 

Precision RTD Handheld Data Logger Thermometer

 

 

 

High Accuracy with 0.01C/F Resolution

Large Backlit Dual LCD Display

MAX/MIN/HOLD Function

16,000 Record Data Logger

USB Cable Included

Windows Software

Auto Power Off

User Offset Adjustable

Low Battery Indicator

Tilt Stand

Precision 4 Wire 100 Ω Platinum RTD Probe Included

The HH376 is a high accuracy RTD thermometer plus a powerful data logger. The unit can store up to 16,000 records at programmed intervals. Windows® based software and USB interface cable are included to allow real time or recorded data to be read by a PC through the USB or RS232 port (RS232 cable is optional). HH376 is supplied with a precision 4-wire RTD probe with automatic locked push-pull connector for easy connection.

SPECIFICATIONS
Instrument
Numerical Display:
 5-digit LCD
Measurement Range: -100 to 400°C (-148 to 752°F)
Resolution: 0.01°C (0.02°F)
Sensor Types: Platinum resistance temperature sensor for pt-100 4 wires, ALPHA = 0.00385

Environmental
Operating Temperature and Humidity:
 0 to 50°C (32 to 122°F); 0 to 80% RH
Storage Temperature: -10 to 60°C (14 to 140°F); 0 to 80% RH; altitude up to 2000 meters
Accuracy: At (23 ±5°C)
Range Accuracy: -100 to 400°C ±(0.05% reading + 0.1°C); -148 to 752°F ±(0.05% reading + 0.2°F)
Temperature Coefficient: For ambient temperatures from 0 to 18°C and 28 to 50°C, for each °C ambient below 18°C or above 28°C add the following tolerance into the accuracy spec. 0.005% of reading + 0.01°C (0.005% of reading + 0.02°F)
Sample Rate: 2 times per second
Dimensions: 185 L x 65 W x 36 mm D (meter only)
Weight: 360 g approx.
Power Requirement: 9V battery (included)
AC Adaptor: 9 Vdc (7 to 10V max)/20 mA
min (plug diameter: 3.5 x 1.35 mm)
Battery Life: Approx. 100 hrs

Probe
Sensor Type:
 Pt100 (4 wire)
Accuracy: Class A13, temperature probe
Measurement Range: -100 to 400°C (-148 to 752°F)
Sheath Diameter: 5.0 mm (0.2")
Sheath Length: 230 mm (9.05")
Cable Length: 1500 mm (59.0")

 

 